Serwer Supermicro SYS-6049GP-TRT
- Processor
- 2nd Gen Intel® Xeon® Scalable processors and Intel® Xeon® Scalable processors
- Memory
- 24 DIMM slots Up to 6TB 3DS ECC DDR4-2933 MHz † RDIMM/LRDIMM Supports Intel® Optane™ DCPMM Memory type 2666/2400/2133MHz ECC DDR4 SDRAM
- Chipset
- Intel® C622
- Graphics Processor
- Supported GPUs: 20 PCI-E 3.0 x16 double/single width cards (full height, full length) NVIDIA T4 PCI-E Gen 3 x16 Switch Interconnect CPU-GPU PCI-E, NVIDIA® NVLink™ bridge (optional)
- Drives
- 24 hot-swap 3.5" drive bays or 22 hot-swap 3.5" drive bays + 2 U.2 NVMe 2.5" drives M.2 interface: 1 PCI-E 3.0 x4 Form factors: 2280, 22110 Key: M-Key
- PCI-Express
- 20 PCI-E 3.0 x16 slots (FHHL) — support for up to 20 single-width NVIDIA T4 GPUs 1 PCI-E 3.0 x8 slot (FH, FL in x16)
- Ports
- 24 SATA3 ports (6 Gb/s) 2 RJ45 10GBase-T LAN ports 1 dedicated IPMI LAN RJ45 port 4 USB 3.0 ports (rear) 1 VGA connector 1 COM port (header)
- On-Board Devices
- SATA3 (6 Gb/s) with RAID 0, 1, 5, 10 Dual port 10GbE from C622
- Monitoring
- IPMI: Intelligent Platform Management Interface v.2.0 support IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
- Graphics
- ASPEED AST2500 BMC
- Fans
- 8x 92 mm RPM hot-swap fans
- Dimensions and Weight
- Height 7.0 "(178 mm) Width 17.2 inches (437 mm) Depth 32.1 inches (815 mm) Net weight: 65.5 lbs (29.7 kg) Gross weight: 100 lbs (45.3 kg)
- Power Supply
- Redundant 2000W power supplies with PMBus
- System BIOS
- BIOS type: AMI 32 MB SPI Flash memory
- Software
- Intel® Node Manager IPMI 2.0 KVM with dedicated LAN SSM, SPM, SUM SuperDoctor® 5 Watchdog
- PC Health Monitoring
- Monitors for CPU cores, chipset voltages, memory. 4+1 phase voltage regulator Fans with tachometer Status monitor for speed control Pulse Width Modulation (PWM) fan connectors CPU and chassis environment monitoring Thermal control for fan connectors
- RoHS
- RoHS compliant
- Operating Conditions
- Operating temperature: 10°C ~ 35°C (50°F ~ 95°F) Non-operating temperature: -40°C to 60°C (-40°F to 140°F) Operating relative humidity: 8% to 90% (non-condensing) Non-operating relative humidity: 5% to 95% (non-condensing)
Potrzebujesz konsultacji technicznej przy wyborze serwera?
Wyślij zgłoszeniew Servermall
gwarancji
testowanie
Chcemy mieć pewność, że nasz sprzęt jest dla Ciebie w pełni niezawodny. Dlatego cały nasz sprzęt (nawet nowy) podlega pełnej diagnostyce, testowaniu i wymianie części.
testowanie
W pełni ładujemy nasz sprzęt różnymi narzędziami i oprogramowaniem. Bądź pewien, że będzie działał przez bardzo długi czas.
Zasilanie
The components work at full capacity and are tested for several days. If we are not sure about something, we replace it.
of all equipment
Our regulations imply the same testing for both used and new equipment. Oh, and by the way, we complement the official manufacturer’s warranty with our own warranty.