Server Supermicro 5019S-ML
- Processor
- Single Socket H4 (LGA 1151) supports: Intel® Xeon® E3-1200 v6/v5, Intel® Core™ i3 7th/6th Gen CPU TDP up to 80W
- Memory Capacity
- 4x 288-pin DDR4 DIMM slots Up to 64GB DDR4 ECC UDIMM Memory type: 2400/2133/1866/1600 MHz ECC DDR4 SDRAM 72-bit, 288-pin (UDIMM) gold-plated DIMM modules DIMM module sizes: 16GB, 8GB, 4GB
- Chipset
- Intel® C236
- I/O Ports
- 8 SATA3 ports (6 Gb/s) 2 RJ45 Gigabit Ethernet LAN ports 1 dedicated IPMI LAN RJ45 port 5 USB 3.0 ports (2 rear + 2 headers + 1 type A) 6 USB 2.0 ports (2 rear + 4 headers) 1 VGA port 2 COM ports (1 rear, 1 header) 2 SuperDOM (Disk on Module) ports with built-in power
- Chassis
- 1U rackmount Model CSE-512F-350B1
- Dimensions and Weight
- Height 9.45 inches (240 mm) x Width 8.27 inches (210 mm) x Depth 14.4 inches (366 mm) Gross weight: 16 lbs (7.3 kg) Net weight: 10.5 lbs (4.8 kg)
- Expansion Slots
- PCI-Express: 1 PCI-E 3.0 x8 (in x16 slot) M.2 M.2 interface: 1 M.2 interface: PCI-E 3.0 x2 M.2 form factor: 2280 M.2 Key: M-Key
- Drive Bays
- 2x 3.5" or 3x 2.5" (option) internal drive bays
- Power Supply
- 350W AC power supply with PFC Platinum
- Environmental Specifications
- Operating temperature: 10°C to 35°C (50°F to 95°F) Non-operating temperature: -40°C to 70°C (-40°F to 158°F) Operating relative humidity: 8% to 90% (non-condensing) Non-operating relative humidity: 5% to 95% (non-condensing)
- Motherboard
- Super X11SSH-F
- Network Controllers
- 2 Intel® I210-AT Gigabit Ethernet LAN ports Supports 10BASE-T, 100BASE-TX and 1000BASE-T, RJ45 output
- IPMI
- Intelligent Platform Management Interface v.2.0 support IPMI 2.0 with virtual media over LAN and KVM-over-LAN support ASPEED AST2400 BMC
- RAID
- SATA3 (6 Gb/s) via C236 controller RAID 0, 1, 5, 10 support
- Video
- ASPEED AST2400 BMC
- Fans
- 2 x 40x56 mm counter-rotating PWM fans
- PC Health Monitoring
- Monitors for CPU cores, +3.3V, +5V, +12V, +5V standby, VBAT, HT, memory, chipset voltages. Total of 5 fan headers supporting up to 5 fans 2 fans with tachometer status monitoring Status monitor for speed control Status monitor for on/off control Low noise fan speed control Pulse Width Modulation (PWM) fan connectors CPU and chassis environment monitoring CPU thermal trip support I2C temperature sensing logic Thermal Monitor 2 (TM2) support PECI System information indicator Suspend static indicator LED UID/remote UID Chassis intrusion detection Chassis intrusion header RoHS, halogen-free
Benötigen Sie eine technische Beratung zur Serverauswahl?
Anfrage einreichenfür den Kauf eines Servers
bei Servermall
Garantie
Wir möchten sicherstellen, dass unsere Geräte für Sie absolut zuverlässig sind. Deshalb werden alle unsere Geräte (auch neue) umfassend diagnostiziert, getestet und Teile ausgetauscht.
Tests
Wir statten unsere Geräte mit verschiedenen Dienstprogrammen und Software aus. Sie werden garantiert lange funktionieren.
Stromversorgung
Die Komponenten arbeiten mit voller Leistung und werden mehrere Tage lang getestet. Bei Zweifeln tauschen wir sie aus.
aller Geräte
Unsere Vorschriften sehen die gleichen Prüfungen für gebrauchte und neue Geräte vor. Übrigens: Wir ergänzen die offizielle Herstellergarantie durch unsere eigene Garantie.